Part 2 – Fixing low voltage problems with our Heatmiser neo Stat 12V V2 Thermostat install

So we had a problem with our installation of the new Heatmiser thermostat. The thermostat is now positioned half way along the boat, before the old thermostat has been in probably the coldest part of the boa, much nearer the original heater controls. Now when the batteries are not fully charged the voltage drop on the 1 mm2 cable can to great to make the Eberspacher Diesel heater fire up reliably.

Problem solved by adding a remote relay

To fix this problem we needed to fit a relay where the old thermostat was positioned and use the Heatmiser thermostat ‘Call for heat’ signal to switch the relay, which would intern switch on the diesel heater.

Heatmiser with Relay
Heatmiser with Relay

The new wiring looks like the diagram above, with the relay much nearer to the heater there is minimal voltage drop from the relay to the heater, while the Heatmiser thermostat is still happy.

The relays I purchased at 12v automotive spec with a way over the top 30A switch capability. They come with a 30A fuse, this is replaced with a 1A fuse for this installation.

Winter Frost Protection Year 2

Last year we set the boat up with two thermostats, a normal one that controls the Eberspächer D4W diesel heater when we need it, initially the heating was just a switch on/off. I also fitted a frost thermostat both of these have a switch so they can be taken out of circuit.

Frost Thermostat
Frost Thermostat

So this year we made sure the diesel tank was fully topped up switch in the frost thermostat as low as I could above freezing (about 2°C).

Update Feb 2023 – This seems to have worked well again this year, we have used a few gallons of diesel, but the boat seems to be free of any frost damage.