Our plan this year was that my brother and his family would start the holiday on the boat taking Floydtilla from Droitwich Spa Marina to somewhere in Birmingham, this would take them up the Tardebigge Lock flight, a task on its own, especially with two young children.
Unfortunately for them their youngest had picked up a tummy bug (The Plague), which over their week spread around the family, and then to make things worse the water pump decided to fail, they made valiant attempts to get things fixed but, in the end, they moored up at Alvechurch Marina and the survivors of the tummy bug travelled out to Birmingham on the train.
So, a week after they had set off, we arrived at Alvechurch Marina to relieve them, by this time my brother was feeling better so we tock him to Droitwich Spa Marina to collect his car and leave ours at the marina, then back to Alvechurch Marina and we took over the plague boat, which they had cleaned every surface ready for us.
We decided we would head back to Droitwich Spa Marina so it’s back down the Tardebigge Lock flight to our home mooring to make repairs.
After a trip to Ikea where we selected some new curtains, that will need to be shortened and adapted, each original made 3 new curtains for the boat after cutting and a new heading tape was fitted.
Sonia is a dab hand at making and adapting these for the boat and these are much more lively than the originals.
This one is in the lounge area, and the ones in the bedroom areas have been fitted with a blackout lining so we can sleep in on bright sunny summer morning…
I selected this one as it gave me the opportunity to connect to my onboard Raspberry Pi which I am using to give some smart boat features and provide live location tracking for my website in the future.
The battery monitor comes in two parts, a display which provides a readout of the battery status and a means of programming/setting up the system for your configuration.
The Shunt
The second part is called a shunt, this needs to be placed, in our case, on the negative side of the battery bank, so that everything must pass through it to reach the battery, there should be no other connections to the negative side of the batteries else your measurements will never be accurate.
A shunt is a resistor of very low but known value that is placed in parallel with a voltmeter so that all the current being measured flows through it. The voltage drop across the shunt’s resistor is measured; this voltage drop across the shunt is proportional to the current flowing and can then be calculated using Ohms law (Current = Volts / Resistance).
Shunts are rated for the maximum current they can measure, in our case 500A which at 12V is 6000W, more than enough for our boat.
The battery monitor also has an extra cable that connects to the positive side of the battery bank to power the electronics and the display, but also to measure the current battery voltage, we have an extra wire connected to the starter battery, so we can monitor its voltage as well.
Peukert’s Law
To then calculate the remaining capacity of the battery, the monitor uses an adaptation of Peukert’s Law** which can be used to calculate the capacity of lead acid batteries at different rates of discharge. As we discussed earlier, the discharge rates affect the battery capacity.
** Developed by Wilhelm Peukert (1855-1932) Peukert’s law is used to calculate the batteries deliverable capacity at the current given rate of discharge, His law describes the batteries capacity at a constant discharge until it reaches its cut off voltage, below which you can damage your battery, this constant is called ‘K’, for example K=1.25 is used for our flooded lead acid batteries. There are however some limitations to this law as it does not consider the batteries temperature or age. I expect each monitor manufacturer modifies this to consider these extra factors when displaying the results, our system records each battery charge/discharge cycle.
The capacity of a battery falls at higher rates of discharge because the chemical reaction within the battery reaches its maximum speed for the given plate size and therefore the voltage drops. If left to recover, that missing capacity will return.
Using these calculations, a battery monitor can calculate the available power remaining while the battery is in use (under load) and as that load changes or even as the battery is charging, it can display the current State of Charge (SOC).
Now you know what is happening?
Armed with this information, you can then decide how you want to operate your boat and if you will need to start the engine to charge the batteries. One of our future projects is to work out the size we need for some solar panels, and we will use the data from the battery monitor to help calculate the size system we need, but that is a topic for another day
The State of Charge (SOC) Calculation Lead Acid batteries
Voltage only gives a rough estimate of State of Charge (SOC), the table below is just an example, the voltages can change significantly when the battery is under load, in most canal boat there is always something using the battery, our fridge while efficient is always on, so to measure this properly you need to have the battery disconnected and allowed to rest for up to a couple of hours (Not always the simplest thing to arrange).
Capacity %
Resting Voltage**
100%
12.70 V
90%
12.50 V
80%
12.42 V
70%
12.32 V
60%
12.20 V
50%
12.06 V
**Note: Example Only – typical lead acid battery. Best to check with your battery supplier if you use this method.
For your battery monitor to be effective you need to get the battery to a known state of charge to set a base/synchronisation point for future calculations. This is typically done when the battery is at 100% State of Charge (SOC).
You can tell when a battery is fully charged by looking at the battery charger. When you charge a battery, the charger will start at its maximum current; this is known as the boost phase, during this, the voltage of the battery will increase to near the gassing voltage.
What is Gassing and why is it so bad
Gassing is basically very bad, as gassing mean that the current applied to the battery is not being used to transform the plates back to their fully charged state but is breaking the water down to Oxygen and Hydrogen, which is a highly explosive mixture, try to remember back to school science lessons and electrolysis.
A smart battery charger will monitor the batteries internal resistance so then when it reaches near 80-85% charged it will switch over to the next phase known as the absorption phase. The last 15-20% will take a lot longer for a battery to absorb. It was explained to me much like the seats in a cinema, when the cinema is empty it is easy to find a seat, but as the cinema fills up the available spaces are harder and harder to find and fill.
The Float Phase
Once charging is complete the charger will switch to the float phase, where the voltage is kept at a point to maintain the battery capacity, this is often referred to as trickle charging.
State of Charge (SOC)
With the battery now at 100% charged, we have our known State of Charge (SOC). A battery monitor can use this to calculate what usable power is available while monitoring further charging and usage of the battery.
If you can afford the initial outlay, there are lots more battery options available that just the original wet Lead Acid batteries, with many variations on the discharge capacity limits. Lithium based batteries for example have almost 100% of the battery’s capacity available, while our wet Lead Acid are limited to just 50% usable capacity.
Lead Acid Types
Wet Cell / Flooded – This is the most basic battery type of battery with lead plates suspended in an electrolyte of sulphuric acid. There have been a few upgrades over the years, but they basically come in two types; user maintained, where you can top up the cells, or sealed for life. They should not be discharged below 50% capacity if you wish to preserve their life. (Typical 12V 100Ah battery £100) £-££
GEL – These batteries use the same chemistry, but the electrolyte has been jellified with silica (Fine Sand), the cells are sealed and under slight pressure, this enables the hydrogen gas created during discharging to be reabsorbed during charging. They are not good as starter batteries as they do not like high current situations. (Typical 12V 100Ah battery £180) £££
AGM – AGM stands for Absorbed Glass Matt; this is where a fine woven glass fibre mat is used to separate and hold the electrolyte in contact with the lead plates. (Typical 12V 100Ah battery £180) £££
Lead Carbon – This is the latest lead acid gel type of battery; they have a lead positive plate and a carbon negative plate, giving them a faster charging capacity, and a prolonged life expectancy. Typical 12V 100Ah battery £250) £££££
Note: Both GEL and AGM batteries come under the overall heading of VRLA (Value Regulated Lead Acid). Both type of batteries can provide more of their available power than a standard lead acid battery up to 70-80% – while Lead Carbon batteries can be discharged to 95%, again subject to the manufacturer’s specification. But be careful; GEL and AGM batteries are much more sensitive to aggressive charging. Under these conditions, the hydrogen cannot be recombined into the gel quickly enough, resulting in damage to the battery.
Lithium Technologies
Lithium-Ion – This is the kind of battery that has made the modern portable device market possible; they can sustain their voltage while under much greater load than Lead Acid type batteries. They have a very low internal resistance so charge much quicker and best of all almost all the battery capacity is available for use. Typically they can be discharged down to 10-20% of their capacity.
At present the downside is the initial cost which can be many times that of lead acid, and they have had a bit of a reputation problem for causing fires. (Typical 12V 100Ah battery £600) ££££££.
Lithium-iron phosphate (LiFePO4) – These are the latest technology with a longer storage shelf life but a bit lower capacity for their size than Lithium-Ion, which should not be much of a factor in a large thing like a canal boat. (Typical 12V 100Ah battery £700) £££££££.
Coming Next
In the next in this series, we are going to look at the State of charge calculation, which is very important if you are a Lead Acid Battery user.
We use cookies on our website to give you the most relevant experience by remembering your preferences and repeat visits. By clicking “Accept”, you consent to the use of ALL the cookies.
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. These cookies ensure basic functionalities and security features of the website, anonymously.
Cookie
Duration
Description
cookielawinfo-checbox-analytics
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Analytics".
cookielawinfo-checbox-functional
11 months
The cookie is set by GDPR cookie consent to record the user consent for the cookies in the category "Functional".
cookielawinfo-checbox-others
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Other.
cookielawinfo-checkbox-necessary
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookies is used to store the user consent for the cookies in the category "Necessary".
cookielawinfo-checkbox-performance
11 months
This cookie is set by GDPR Cookie Consent plugin. The cookie is used to store the user consent for the cookies in the category "Performance".
viewed_cookie_policy
11 months
The cookie is set by the GDPR Cookie Consent plugin and is used to store whether or not user has consented to the use of cookies. It does not store any personal data.
Functional cookies help to perform certain functionalities like sharing the content of the website on social media platforms, collect feedbacks, and other third-party features.
Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics the number of visitors, bounce rate, traffic source, etc.
Advertisement cookies are used to provide visitors with relevant ads and marketing campaigns. These cookies track visitors across websites and collect information to provide customized ads.